Products & Services
Background:Manganese is abundantly distributed over the surface of the globe. It enters the water body through circulation under particular environment conditions. Human activities, such as ore dressing, smelting, and chemical practices, can also produce large amount of Manganese-containing waste water. Compound form Manganese can be of various valents, mainly bivalent, trivalent, tetravalent, hexavalent and 7-valent. Due to lack of oxygen, manganese exists as soluble bivalent compound in ground water. In surface water, it can also presence as soluble trivalent complex compound and tetravalent suspended substances. Although trace amount of manganese is innocuous, It may cause harm to drinking water, industry production when its content is over certain level. Water of high manganese content tend to appear a color and taste metallic when used for drinking. Long term intake may result in physiological effects; when used for printing and dyeing , textile , paper and other industry purpose, it may form color spot on the surface of the products, undermining the quality; when used as circulation water, it may deposit in the pipe as scale , or cause the failure of ion exchange resin. Therefore, it is highly necessary to control and test the water manganese content. As the traditional test method for manganese is complicated, the R&D team of Thaile Chemical has successfully developed “Thaile” manganese test kit for quick on-spot testing. The new test kit can greatly simplify the operation and significantly lower the testing cost with reliable testing result.
Principle:Testing based on national standard.
Purpose:Quick and accurate test of water manganese content. On-spot quick test in various water consumption field, including industry, agriculture, aquiculture, healthcare, environment and domestic.
Features:
1.Quick and easy:No special training is required, as long as the user follows the instruction. It takes only 15 minutes to finish a test for one water sample.
2.Accurate and reliable:With test results equivalent to what national standard suggests, it is an alternative of the method introduced in the national standard.
3.Highly sensitive:The reagent is highly sensitive to manganese, with precision as high as 0.1mg/L.
4.Affordable: Cost per test is low.
5.Portable:Compact in size, lightweight, and suitable for on-spot quick test.
Operation:
1.Wash the colorimetric tube twice with water sample. Then, measure and take certain amount of water using the colorimetric tube. Adjust the level to the graduation mark of 15ml using a plastic dropper.
2. Ladle 2 flat ladles (use the colorimetric card to cut the powder so that it levels with the rim of the ladle)of Reagent I and add it into the colorimetric tube. Agitate the solution to make the powder dissove in the solution.
3. Add 1 flat ladle of Reagent Ⅱinto the colorimetric tube and agitate the solution to make the powder dissove in the solution
4. Then start colorimetric test after waiting 10 minutes. Vertically place the colorimetric tube 1cm above the blank area of the colormetric card and visually compare the colors from above. Read the manganese content of the water sample by finding the color code that appear the same color as that of the liquid in the tube.
Notes:
1.This product has a detectable manganese content range of 0.1-10.0mg/L. If the manganese content of the water sample is higher than the upper limite of the detectable range , dilute the water sample before testing.The actual result is obtained by timing the reading with corresponding dilution ratio.
2.If there are agglomerations in the powder, smash them with the ladle before using it. As the reagent is in excessive amount, small amount variation each time after cutting flat the powder will not affect the test result
3.If the water sample appear turbid, filter the sample , or stand the sample until it is clear, then take sample from the upper part, before testing.
4.Try to compare the colors in bright light.
5.The pH of the water sample shall be controlled in the range of 5-10.
6. As oxidants or reductants may interfere the testing, it is recommended to add some nitric acid or sulfuric acid then heat to decompose it before testing.
7. When ladling reagent, do not mix up the ladles, use ones with colors that corresponding to the label of the bottles.
8. In case of skin or eye contact of the reagent, just wash it away with water. As reagent I is alkalescent, keep it away from body.
9.After use, please tighten the cap to avoid ineffectiveness.
Liability:The manufacturer and its authorized agents are free from any liabilities due to accidental intake of children and misunderstanding or misuse of the users. If the results of test are dubious, please present the sample to authoritative laboratory for further test.
Appearance:ReagentⅠ: white powder ReagentⅡ: white powder
Specifications:ReagentⅠ: 5g ReagentⅡ: 2.5g (25 times per kit)
Including:ReagentⅠ、Ⅱ: 1 pc respectively; Colorimetric Tube: 1pc; Plastic Dropper: 1 pc; Ladle : 2 pcs;
Colorimetric Card: 1 pc; Users’Manual: 1 pc
Package:HDPE Bottle, Carton
Standard:QB-TCS-WTR-2011
Validity:1 year
Store:Store in a cool and shady place out of reach of children.
Manufacturer:Ningbo Thaile Chemical Technology Co., Ltd
Website: http://m.8qqos3p5ki.com http://nbtlhg.1688.com
Previous:Total Iron Test Kit